Qudi
|
Retrieve live data from InfluxDB as if the measurement device was connected directly. More...
Public Member Functions | |
def | on_activate (self) |
Activate module. | |
def | on_deactivate (self) |
Deactivate module. | |
def | connect_db (self) |
Connect to Influx database. | |
def | getProcessValue (self) |
Return a measured value. | |
def | getProcessUnit (self) |
Return the unit that the value is measured in. More... | |
![]() | |
def | __init__ (self, manager, name, config=None, callbacks=None, kwargs) |
Initialise Base class object and set up its state machine. More... | |
def | log (self) |
Returns a logger object. | |
def | is_module_threaded (self) |
Returns whether the module shall be started in a thread. | |
def | on_activate (self) |
Method called when module is activated. More... | |
def | on_deactivate (self) |
Method called when module is deactivated. More... | |
def | getStatusVariables (self) |
Return a dict of variable names and their content representing the module state for saving. More... | |
def | setStatusVariables (self, variableDict) |
Give a module a dict of variable names and their content representing the module state. More... | |
def | getConfiguration (self) |
Return the configration dictionary for this module. More... | |
def | get_connector (self, connector_name) |
Return module connected to the given named connector. More... | |
![]() | |
def | __new__ (cls, name, bases, attrs) |
Collect declared Connectors, ConfigOptions and StatusVars into dictionaries. More... | |
Public Attributes | |
conn | |
![]() | |
module_state | |
connectors | |
Static Public Attributes | |
user = ConfigOption('user', missing='error') | |
pw = ConfigOption('password', missing='error') | |
dbname = ConfigOption('dbname', missing='error') | |
host = ConfigOption('host', missing='error') | |
port = ConfigOption('port', default=8086) | |
series = ConfigOption('dataseries', missing='error') | |
field = ConfigOption('field', missing='error') | |
cr = ConfigOption('criterion', missing='error') | |
Retrieve live data from InfluxDB as if the measurement device was connected directly.
Example config for copy-paste:
influx_data_client: module 'influx_data_client.InfluxDataClient' user 'client_user' password 'client_password' dbname 'db_name' host 'localhost' port 8086 dataseries 'data_series_name' field 'field_name' criterion 'criterion_name'
def influx_data_client.InfluxDataClient.getProcessUnit | ( | self | ) |
Return the unit that the value is measured in.